Huawei RH 1288A V2 server Overview

Huawei RH1288A V2 rack server is designed for compute intensive and cloud applications. This high-performance 1U rack server supports 2 Intel Xeon E5-2600 V2 series processors, 8*DDR3 RDIMMs/LRDIMMS slots, 8*2.5” SAS/SATA HDDs or SSDs or 4*3.5” SAS or SATA HDDSs. This server supports 2 GE ports without occupying any PCIe slots, improving network availability. Moreover, Dynamic energy-saving and power-capping technologies limit server power consumption to a preset threshold, improving overall energy efficiency.

Quick Specs

Figure 1 shows the appearance of Huawei RH 1288A V2 server.

The RH1288A V2 has the following two models:

The RH1288A V2-8S supports eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs. Figure 1-1 shows the RH1288A V2-8S appearance.

The RH1288A V2-4L supports four 3.5-inch SAS or SATA HDDs. Figure 1-2 shows the RH1288A V2-4L appearance.

Figure 1-1  RH1288A V2-8S appearance.

Figure 1-2  RH1288A V2-8S appearance.

Table 1 shows the Quick Specs.

Product Huawei RH 1288A V2 server
Processors 1 or 2 Intel® Xeon® E5-2600 v2 series processors
Memory 8 DDR3 RDIMMs/LRDIMMs
Internal Storage Hard disk configurations:
● 8 x 2.5-inch SAS/SATA HDDs or SSDs
● 4 x 3.5-inch SAS or SATA HDDs
RAID Support ●RAID 0, 1, 10, 5, 50, 6, or 60
● Supercapacitor
● RAID state migration, configuration memory, self-diagnosis, and web-based remote configuration
LOM Network Ports Network configuration: 2 x GE electrical ports
PCIe Expansion Up to 3 PCIe slots
Fan Modules 5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans
PSUs 2 hot-swappable PSUs in 1+1 redundancy mode
Management Uses Huawei Hi1710 management chip and independent ports, supports standard management interfaces, such as SNMP and IPMI, and provides a GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring
Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft SystemCenter, and Nagios
Operating Temperature 5ºC to 35ºC (41ºF to 95ºF)

 Product Details

Figure 2 shows the front panel of Huawei RH 1288A V2 server.

Figure 2-1  RH1288A V2-8S front view.

 

Note:

UID button/indicator Power button/indicator
USB port USB port
Ethernet port indicator 1 Ethernet port indicator 2
Healthy indicator VGA port
Hard disk Captive screw
Hard disk fault indicator Hard disk active indicator
Label (including the ESN label) Built-in DVD-ROM drive
Hard disk slot label    

Figure 2-2  RH1288A V2-4L front view.

 

UID button/indicator Power button/indicator
USB port USB port
Ethernet port indicator 1 Ethernet port indicator 2
Healthy indicator Hard disk
Captive screw Hard disk fault indicator
Hard disk active indicator Label (including the ESN label)
Hard disk slot label  

Figure 3 shows the back panel of Huawei RH 1288A V2 server.

 

Note:

Connection status indicator GE port
Data transmission status indicator GE port
UID indicator Management network port (Mgmt)
USB port USB port
VGA port Serial port
PSU power port PSU indicator
PSU PSU power port
PSU indicator 16 PSU

Compare to Similar Items

Table 3 shows the comparison of Huawei RH 1288A V2 server and Huawei RH1288 V2 Rack Server.

Product Huawei RH 1288A V2 server Huawei RH1288 V2 Rack Server
Processors 1 or 2 Intel® Xeon® E5-2600 v2 series processors One or two Intel Xeon E5-2600 or E5-2600 v2 series processors
Memory 8 DDR3 RDIMMs/LRDIMMs 24 DDR3 RDIMMs/LRDIMMs
Internal Storage Hard disk configurations:
● 8 x 2.5-inch SAS/SATA HDDs or SSDs
● 4 x 3.5-inch SAS or SATA HDDs
Hard disk configurations:
● 8 x 2.5-inch SAS/SATA HDDs or SSDs
● 4 x 3.5-inch SAS or SATA HDDs
LOM Network Ports Network configuration: 2 x GE electrical ports Network configuration: two or four GE ports or two 10 GE ports
Fan Modules 5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans Seven hot-swappable fan modules in N+1 redundancy mode
Each fan module consists of two counter-rotating fans.

 

Huawei RH 1288A V2 server Specification

Huawei RH 1288A V2 server Specifications

Technical Specifications

Form factor 1 U rack server
Processor Up to two Intel® Xeon® E5-2600 v2 series processors:

·Number of cores per processor: 10 cores (2.4 GHz), 8 cores (2.6 GHz), 6 cores (2.6 GHz), and 4 cores (2.5 GHz)

·Number of QPI links: 2

·Maximum transmission speed per QPI link: 8.0 GT/s

·Maximum memory speed: 1866 MHz

·Maximum L3 cache capacity: 25 MB

Up to two Intel® Xeon® E5-2600 series processors:

·Number of cores per processor: 8 cores (2.2 GHz), 6 cores (2.5 GHz), and 4 cores (2.4 GHz)

·Number of QPI links: 2

·Maximum transmission speed per QPI link: 8.0 GT/s

·Maximum memory speed: 1600 MHz

·Maximum L3 cache capacity: 20 MB

Chipset Intel C602
DIMM ·Up to 8 DIMM slots (4 DIMMs per processor) for installing either RDIMMs or LRDIMMs

·8 x 32 GB RDIMMs for two processors, with a maximum memory capacity of 256 GB

·8 x 32 GB LRDIMMs for two processors, with a maximum memory capacity of 256 GB

·Maximum memory speed: 1866 MHz (E5-2600 v2)

·Data protection measures: ECC, memory mirroring, Single Device Data Correction (SDDC), memory sparing, and lockstep

Storage ·The RH1288A V2 supports the following hard disk configurations:

·RH1288A V2-8S: eight front 2.5-inch SAS HDDs (7.2 TB), SATA HDDs (8 TB), or SSDs (4.8 TB)

·RH1288A V2-4L: four front 3.5-inch SAS HDDs (4 TB) or SATA HDDs (16 TB)

·Hard disks are hot-swappable.

·The server supports RAID 0, 1, 10, 1E, 5, 50, 6, and 60. It protects cache data from power failures, and supports RAID state migration, RAID configuration memory, self-diagnosis, and web-based configuration.

·The mainboard can be configured with a SAS adapter or SAS RAID controller card (with a maximum of 1 GB cache) to improve hard disk storage performance and ensure user data security.

·The RAID controller card does not occupy a standard PCIe slot, improving system scalability.

Network port Two GE ports (Intel I350) on the mainboard, supporting NC-SI, WOL, and PXE
PCIe slot The server provides three PCIe slots: one for a full-height full-length PCIe card, one for a half-height half-length PCIe card, and one for a non-standard RAID controller card.

One Huawei PCIe intelligent network interface card (iNIC), which improves the I/O bandwidth and throughput.

One Huawei SSD card, which greatly improves I/O performance for search, cache, and download services.

NVS315 GPU.

Port Ports on the front panel:

Two USB 2.0 ports

One DB15 video port (provided by the RH1288A V2-8S)

Ports on the rear panel:

Two USB 2.0 ports

One DB15 video port

One DB9 serial port

One RJ45 system management port

One built-in USB port (for the embedded system management program)

Fan module Five hot-swappable fan modules, tolerating the failure of a single fan. Each fan module consists of two counter-rotating fans.
PSU Two hot-swappable 460 W AC PSU in redundancy mode, supporting efficiency of up to 94 percent.
System management UEFI

Huawei iBMC: supports Intelligent Platform Management Interface (IPMI), Serial over LAN (SOL), KVM over IP, and virtual media, and provides one 10/100/1000M RJ-45 management network port.

NC-SI

Security Power-on password

Administrator password

GPU The mainboard integrates the SM750 display chip and provides 32 MB display memory. The maximum resolution is 1920 pixels x 1200 pixels at 60 Hz with 16 M colors.
Physical Specifications
Dimensions (H x W x D) 43.6 mm x 447 mm x 740 mm (1.78 in. x 17.05 in. x 29.13 in.)
Installation dimensions The RH1288A V2 fits into a common rack complying with the IEC 297 standard.

Rack width: 19 in.

Rack depth: > 1000 mm (39.37 in.)

Guide rail installation requirements are as follows:

L-shaped guide rails: apply only to Huawei racks.

Adjustable guide rail: The distance between the front rear mounting bars is 557 mm to 862 mm.

Power rating 460 W
Weight in full configuration Net weight:

RH1288A V2-8S: 19.6 kg

RH1288A V2-4L: 20 kg

Packaging materials: 5.3 kg (11.69 lb)

Input voltage AC: 100-240 V AC (with an input frequency of 50 Hz or 60 Hz)

240 V HV DC: 192-288 V DC

NOTE:

The recommended current specification for the external power circuit breaker connected to the RH1288A V2 is 32 A.

Temperature Operating temperature: 5°C to 35°C (41°F to 95°F)

Storage temperature: –40°C to +65°C (–40ºF to +149ºF)

Temperature change rate: < 20°C/h (36°F/h)

Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)

Altitude ≤ 3000 m (9842.40 ft) When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1°C (33.8°F) per 300 m (984.24 ft).
Humidity Operating humidity: 8% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Humidity change rate: < 20% RH/hour

Long-term storage humidity: 30% RH to 69% RH (non-condensing)

Acoustic Noise The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

Idle:

LWAd: 5.9Bels

LpAm: 43dBA

Operating:

LWAd: 6.7Bels

LpAm: 50.1dBA

NOTE:

The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.